Noran Freedom Si(Li) Peltier X-Ray Detector SEM REM TEM EDS EDX

Artikelnummer: 616

Kategorie: Transmission-, Rasterelektronenmikroskope (REM, TEM)


3.570,00 €

inkl. 19% USt. ,

Lieferzeit: 2 - 3 Werktage



Manufacturer: Noran

Model: Noran Freedom Peltier X-Ray Detector

Description:

X-ray detectors used in energy-dispersive spectrometry (EDS) require some means  of cooling the detector to very low temperatures to obtain the best spectral results. Conventional EDS detectors use liquid nitrogen for  this purpose. The FREEDOM detector uses a thermoelectric cooler instead of a liquid nitrogen dewar to maintain low temperatures. This method has  many advantages, including:

? Reduced detector maintenance. In conventional liquid nitrogen detectors,  levels of liquid nitrogen in dewars must be monitored, and dewars must be  refilled
periodically.
? Reduced detector size. The FREEDOM electrically cooled detector takes up much  less space than a conventional detector with a liquid nitrogen dewar.

Requirements:

To use the FREEDOM detector, the VOYAGER must be equipped with:
? A bias pulse processor printed circuit board
? An analog-to-digital converter/multi-channel scaler (ADC/MCS) printed circuit  boar

Specifications and Installation Requirements:

Environmental
Temperature: 0° C to 30° C (32° F to 86° F) operational
0° C to 35° C (32° F to 95° F) storage
Relative humidity: Less than 90% R.H., no condensation

Electrical
Power Requirements: 100 to 240 volts; 2 amps maximum
Power Supply: Output 19 volts DC at 1 amp, 5-15 volts DC at 5 amps, 5-15 volts  DC at 4.2 amps,
or 12 volts DC at 250 milliamperes.

Physical
Dimensions Detector housing: 188 mm (7.38 in.) wide × 108 mm (4.25 in.) deep ×  133 mm
(5.25 in.) high
Tube lengths: 254 mm (10 in.) and 16 in. (406 mm)
Tube diameter: 16 mm (0.625 in.)
Power supply: 191 mm (7.5 in.) wide × 121 mm (4.5 in.) deep × 356 mm (14 in.)  high
Weight Detector: 5.5 kg (12 lb)
Power Supply: 5.0 kg (11 lb)

Cooling Water
Condition: Softened water preferred.
Connections: 1/4-in. NPT female water outlet required on site with shutoff valve
Standard standpipe drain or 1/4-in. NPT female inlet to drain required.
Water supply tubing: 7.62 m (25 ft), supplied with detector
Drain supply tubing: 7.62 m (25 ft), supplied with detector
Temperature: 15° C (60° F) or less
Flow rate: At least 1 liter per minute (15 gal/hr)

Items delivered:

- Noran Freedom Si(Li) Peltier X-Ray Detector
- Instruction Manual as PDF via E-Mail

The detector is in good cosmetic condition and 100% funtioanl tested & sorted  out.

Bitte melden Sie sich an, um einen Tag hinzuzufügen.