Tecan Microplate Power Washer PW 384 96 Well Cell-based and ELISA Mikroplatten

Artikelnummer: 745

Kategorie: Microplate Reader / Washer


2.975,00 €

inkl. 19% USt. ,

Lieferzeit: 2 - 3 Werktage



 

Manufacturer: Tecan

Model: Power Washer 384

S/N: 510000011

P/N: 16029900

Description:

The Power Washer 384 is ideal for enzyme immunoassays and cell-based assays, in  either 96- or 384-well microplate formats. It has advanced wash-heads for simultaneous processing of all wells in either format, reducing the overall  plate processing time to just a couple of seconds and enabling maximum  throughput. Additionally, the PW384 is fitted with an aerosol shield to protect the user  from potentially infectious aerosols, and productivity is further increased by automated switching between up to three different buffers.

Wash parameters such as dispense and aspiration speed, vertical aspiration  position and vacuum level can be fine-tuned to ensure the best results for your application using the simple WinWash plus package, and up to 20 different  washing programs can be stored.

The Power Washer 384 is fully compatible with Tecan?s Freedom EVO® liquid  handling workstations and the Connect? microplate stacker system. Alternatively, the washer can be operated as a stand-alone instrument and is straight forward  to program using the integrated keypad.

The instrument is easy to maintain and comes with fully automated cleaning  procedures, ensuring high reliability. To further improve walkaway time and  process security, the instrument can be fitted with options including large volume  bottles and liquid level control for both buffer and waste bottles

Product hightlights include:

? High performance washer for 96- and 384-well microplates
? 2-in-1 solution combining two applications and two
? microplate formats in one compact instrument
? Easy, user-exchangeable wash heads guarantee optimum
? throughput in both 96- and 384-well formats
? Simultaneous processing of all wells also in the 384-well format - no  time-consuming indexing of wash head required
? Tunable wash parameters for best results with both cell-based and ELISA assays  for research use
? Handling of up to 3 wash buffers for maximum application flexibility
? Easy programming via integrated keypad or via WinWash? plus software
? Reliable operation and easy maintenance via predefined cleaning protocols
? Aerosol cover around wash head for maximum user safety
? Optional large volume bottle set and liquid level control for process  monitoring of wash buffer and waste bottles
? Full compatibility with Freedom EVO®, TRAC? and Connect? system

Specifications:

Applications: EIA and Cell based assays
Microplate formats: 96- and 384-wells
Mode of plate processing: all wells simultaneously
Manifold channels: 96, 384
Wash-liquid channels: Up to 3
Wash program storage: Up to 20
Dispense volume range: 50-3000 µl in 96 format
10-1000 µl in 384 format
Dispensing accuracy: CV = 2% over 96-well plate
CV = 3% over 384-well plate
Residual volume: = 2 µl across 96-well plate
= 2 µl across 384-well plate

Items delivered:

- Tecan Powerwasher 384 (for 384- & 96-Well)
- Power Cord
- Instruction Manual as PDF via E-Mail

The instrument is fully functional tested - Used but good cosmetic condition.