Eaton Singer Ailtech Stoddart NM-37/57 EMI/Field Intensity Meter 1000MHz 140dB
Manufacturer: SINGER / EATON Corp.
Model: NM 37/57 SL-A S/N: 180
Description:
The NM-37/57 (Ailtech, Singer, Stoddart) EMI/Field Measuring Receiver (Field Intensity Meter) performs manual or programmable EMI emission measurements from 30 MHz to 1000 MHz.
Four switchable bandwidths: 10 kHz, 100kHz, 1 MHz
It incorporates an internal solid-state impulse generator as calibration source.
Easy-to-read 60 dB meter scale and 80 dB attenuator (5 steps).
Overall measurement range: 140 dB (0.1 µV to 1.0 V)
Mains operation as well as internal or external battery operation.
Detector Functions:
- Field intensity
- Quasi peak
- Peak
- Slideback peak
Items delivered:
- EATON NM 37/57
- Power Cord
The instrument is in used cosmetic conditiond and 100% functional tested.
Hersteller: SINGER / EATON Corp.
Modell: NM 37/57 SL-A S/N: 180
Beschreibung:
Der NM-37/57 (Ailtech, Singer, Stoddart) Störmessempfänger (FeldstärkeMessgerät) bietet einen Frequenzbereich von 30 MHz bis 1000 MHz.
Der Messbereich ist unterteilt in 8 Bereiche.
3 umschaltbare Bandbreiten: 10 kHz, 100kHz, 1 MHz
Pegelbereich: 140 dB (0,1 µV- 1V)
Leicht ablesbare 60 dB-Skala und 80 dB-Abschwächer (5 Stufen).
Eingebauter Kalibrator Bandüberwachung im Wobbelbetrieb - Ausgabe auf XY-Schreiber möglich.
Netz- oder Batteriebetrieb (eingebaute Akkus) oder externe Batterie.
Betriebsarten:
- Feldstärke
- Quasi Peak
- exponentielles Abklingverhalten
- Peak
- RMS
- Slideback peak
- manuelle Kompensation
Lieferumfang:
- EATON NM 37/57
- Stromkabel
Model: NM 37/57 SL-A S/N: 180
Description:
The NM-37/57 (Ailtech, Singer, Stoddart) EMI/Field Measuring Receiver (Field Intensity Meter) performs manual or programmable EMI emission measurements from 30 MHz to 1000 MHz.
Four switchable bandwidths: 10 kHz, 100kHz, 1 MHz
It incorporates an internal solid-state impulse generator as calibration source.
Easy-to-read 60 dB meter scale and 80 dB attenuator (5 steps).
Overall measurement range: 140 dB (0.1 µV to 1.0 V)
Mains operation as well as internal or external battery operation.
Detector Functions:
- Field intensity
- Quasi peak
- Peak
- Slideback peak
Items delivered:
- EATON NM 37/57
- Power Cord
The instrument is in used cosmetic conditiond and 100% functional tested.
Hersteller: SINGER / EATON Corp.
Modell: NM 37/57 SL-A S/N: 180
Beschreibung:
Der NM-37/57 (Ailtech, Singer, Stoddart) Störmessempfänger (FeldstärkeMessgerät) bietet einen Frequenzbereich von 30 MHz bis 1000 MHz.
Der Messbereich ist unterteilt in 8 Bereiche.
3 umschaltbare Bandbreiten: 10 kHz, 100kHz, 1 MHz
Pegelbereich: 140 dB (0,1 µV- 1V)
Leicht ablesbare 60 dB-Skala und 80 dB-Abschwächer (5 Stufen).
Eingebauter Kalibrator Bandüberwachung im Wobbelbetrieb - Ausgabe auf XY-Schreiber möglich.
Netz- oder Batteriebetrieb (eingebaute Akkus) oder externe Batterie.
Betriebsarten:
- Feldstärke
- Quasi Peak
- exponentielles Abklingverhalten
- Peak
- RMS
- Slideback peak
- manuelle Kompensation
Lieferumfang:
- EATON NM 37/57
- Stromkabel
Versandgewicht: | 31,50 Kg |