New Brunswick Innova 4000 Incubator Orbital Shaker Inkubationsschüttler 60°C

Artikelnummer: 3011

Kategorie: Schüttler / Vortexer / Mischer


2.900,00 €

inkl. 16% USt. , zzgl. Versand (Spedition)

momentan nicht verfügbar


Manufacturer: New Brunswick

Model: Innova 4000 Incubator Shaker

P/N: M1192-0002

S/N: 891220289

Description:

The New Brunswick Innova 4000 Incubator Shaker offers rigid temperature and agitation control in a benchtop design. This large-capacity shaker can culture a wide array of samples in test tubes and flasks. The Innova 4000?s microprocessor controls allow for uniform heating and motion and accurate regulation of shaking speed, automatically compensating for changes in temperature using a large capacity blower. The system includes many safety feature, such as automatic cut-out when lid is opened, fail-safe thermostat for high temperature, and standard audible and visual alarms with timer.
Recommended for various molecular biology techniques, including hybridization studies, plasmid preps, DNA fingerprinting and more.

Features:

- Shaking:
Speed: 25-500 RPM
Motion: 19 mm diameter circular orbit
Indication: LED digital electric display, 1 RPM increments
Setpoint & Control: Digital adjustment with PI microprocessor control and instantaneous visual feedback
Accuracy: +/- 1 RPM
- Drive:
Triple eccentric counterbalanced ball bearing drive
- Temperature:
Range: 5°C above ambient to 60°C
Control Stability: +/-0.1°C by use of PI microprocessor controller and pulse width modulation of heater
Setpoint: Digital adjustment increments within 0.1°C instantaneous visual feedback
Accuracy: +/- 0.1°C @ 30-40°C range
Uniformity: +/- 0.5°C for remaining range
Safety: Better than 0.5°C
Heater shuts off if temperature exceeds operating range
Heater: Low watt density resistance heater with high temperature safety thermostat
- Timer:
programmable shaking periods from 0.1 to 99.9 hours by a digital timer that shuts off at the end of period and energizes status light
timer counts down and digital display indicates remaining time
can be deactivated for continuous operation
additionally, unit will display total accumulated running time for service information
- Self-diagnostic status:
Warning signal (audible and visible) indicates when shaking speed deviates more than 5 RPM or the temperature deviates more than 1.0°C from set point and when timer operations has expired. Audible alarm can be deactivated/activated by the operator.
- Motor:
1/15 HP, 3 Phase brushless ball bearing DC motor.
- Construction:
heavy gauge steel, phosphate-coated and texture painted cabinet. See-through plastic cover.

Specifications:

- Agitation: 25 to 500 rpm, ±1rpm
- Maximum Capacity: 18 x 250 mL flasks on universal platform
- Platform Size: 46 x 46 cm, Phenolic composite
- Chamber dimensions (interior) (W x D x H): 50.2 x 48.3 x 33.6 cm above the platform
- Dimensions (exterior) (W x D x H): 53.4 x 69.9 x 50 cm
- Temperature Range: 5° above ambient to 60°C
- Power: 230 V 50/60 Hz
- VA Requirements: 600 VA

Items delivered:

- New Brunswick Innova 4000 Incubator Shaker
- Instruction Manual as PDF via E-Mail request

Condition:

The Incubator Shaker is in used but good cosemtic condition. It functions as intended and is 100% functional tested, ready to be operated.


Versandgewicht: 50,00 Kg