Manufacturer: Copley Ltd.
Model: Breathing Simulator Model BRS 3000
S/N: 21558
P/N: 9121
Description:
The Breathing Simulator Model BRS 3000 is similar in design and operation to the BRS 2000 except that it has a volume of 500 mL - 5 Litres (certified). It also features a maximum flow rate of 240 L/min (free flow) and a maximum acceleration of 25 L/s2 (free flow) making it the ideal unit for the testing of MDIs and DPIs for improved IVIVCs. Delivered Dose Uniformity (DDU) and Aerodynamic Particle Size Distribution (APSD) continue to be subjects of close scrutiny as the concept of Quality by Design (QbD) becomes more widespread. The emphasis is now on method development that uses design of experiments (DoE) to identify the most significant factors, the critical quality attributes (CQAs), relevant to the product concerned.
If you are also interested in purchasing a NGI Next Generator Impactor, TPK 2000 Critical Flow Controller, DUSAs or other different Adapters, Artificial Throats or any other accessory just ask for it - we have a big quantities in stock.
Key Facts:
- Volume (computer controlled): 0 to 5000 mL
- Frequency: 0+ (upper defined by acceleration limit)
- I:E Ratio: variable
- Waveforms: Sinusoidal, Square, Triangular, User defined (flow vs time)
- Tidal breathing profiles: Inhalation and exhalation
- Inhalation only profiles User defined profiles (flow vs time)
- User Interface: Embedded computer (Windows XP)
- Uses:
Limited testing of Nebulisers (Ph.Eur. 2.9.44 and
USP <1601>) and MDIs with Spacers/VHCs-
(USP <1602>)
Improving IVIVCs for MDIs and DPIs:
- With DUSA for MDI/DPI (Dose Uniformity)
- With Impactor and Mixing Inlet (APSD)
Items delivered:
- Copley Breath Simulator Model BRS 3000
- Coply Alberta Idealized Throat (AIT) in Aluminium (Adult version) (P/N 8511)
- Copley Alberta Idealized Throat to NGI/FSI Adapter (P/N 8513)
- Copley Flow Meter to Alberta Idealized Throat Adapter (P/N 8514)
- different Copley Mouthpiece Adapter for AIT (Discus, Turbuhaler, Handihaler, etc.) (P/N 8515)
- Copley Spare Silicone Seal for Alberta Idealized Throat (P/N 8516)
- Copley Leak Test Inlet Cap and Outlet Adapter (P/N 8518)
- Copley Mixing Inlet for ACI, FSA and MSLI (P/N 8325)
- Copley Adapter for use with NGI and FSI (P/N 8326)
- Copley IQ/OQ/PQ Documentation for BRS 3000 (P/N 9106A)
- Copley Adapter for use with DUSAs for MDIs & DPIs (P/N 9122)
- Copley Adapter and Flow Control Valve for use with Mixing Inlet (P/N 9123)
- Copley BRS 1100/2000/3000 Qualification Kit (P/N 9105)
- Copley Critical Flow Controller Model TPK 2000 (P/N 8760)
Everything you see on the pictures is part of the delivered items.
If you are also interested in purchasing a NGI Next Generator Impactor, TPK 2000 Critical Flow Controller, DUSAs or other different Adapters, Artificial Throats or any other accessory just ask for it - we have a big quantities in stock.
The Breath Simulator BRS 3000 is in absolutely excellent condition and 100% functional tested.
It has been serviced regularly and all documentation is coming with the delivery of the system.
Buy with confidence!